Solis RSS
Connecting a Generator to a Solis Hybrid Inverter: Hyundai & Solis S6 Guide
How generator start controls, Solis S6 hybrid inputs and battery charging fit together — with practical equipment checks before you order.
Solis Inverter and Battery Compatibility List (Updated Weekly)
Last checked against the official Solis list: 14 October 2026. This page is reviewed automatically every week and is updated when the manufacturer document changes. Battery compatibility is not a brand-level yes or no. The exact Solis inverter family, voltage class, battery model, battery-management-system protocol and the market in which the equipment is installed all matter. Use the written list below to narrow the search, then confirm the final pairing in the current Solis document and with the installer before ordering or commissioning equipment. Solis warns that compatibility can vary by market and that using a battery outside the approved...
Why Your Solis Battery Is Not Charging or Discharging When Expected
If your Solis battery is not charging or discharging when you think it should, the cause is often a visible setting (mode, time schedule, reserve) or a system limitation that changes what is achievable in practice. This guide keeps you within a safe homeowner boundary: observe what the system is doing, record the key settings and messages, and escalate with good evidence. Do not change protection settings, grid code settings, firmware, battery parameters, or any battery communications wiring (CAN/DIP/RS485). Before you start: confirm what you have (and stop if unsure) This guide is written for the Solis S6-EH1P(3–8)K-L-PLUS European range...
Solis 1015 NO-GRID or AC Breaker Tripping: What It Means and What to Do Next
Solis 1015 NO-GRID or AC Breaker Tripping: What It Means and What to Do Next This guide helps you understand the Solis alarm 1015 NO-GRID / AC MCB tripping at a high level, record useful evidence, and recognise when a qualified installer/electrician or Solis support is required. It stays within a strict homeowner safety boundary: observation only, normal app/router checks, evidence gathering, and escalation. What “1015 NO-GRID / AC MCB tripping” indicates (high level) Solis describes alarm 1015 as “NO-GRID / AC MCB tripping” in its support resources. In practical terms, this label suggests the inverter is detecting a grid/AC...
How to Find Solis Inverter Alarm History and Gather the Information Support Needs
If your Solis inverter shows an alarm (or your app reports a fault), the fastest way to get help is to capture the exact alarm details and supporting evidence before you contact your installer or Solis support. This guide keeps you within a read-only boundary: you will only navigate display/app menus and collect information. You will not change settings, clear protections, or apply steps meant for a different Solis family. Safety boundary (please read first) Do not open the inverter, remove covers, or touch any cabling or terminals. Do not change settings or configuration while looking for alarms (avoid any...