The three labelled lights describe separate parts of the monitoring path. PWR is power, COM is logger-to-inverter communication, and NET is the connection to the Solis server. Reading them separately avoids assuming an inverter fault. Scope and safety This guide is for the S2-WL-ST, S3-WiFi-ST, S4-WiFi-ST and S5-WiFi-ST models covered by Solis's current support article, including USB and four-pin versions. Indicator layouts and behaviour on older DLS-W, GPRS, LAN-only or other logger families may differ. Observe the label and lights only. Do not remove, rotate or reseat an installed logger, open the inverter or touch wiring. Solis says an installed...

Read more

Dyness, Guides, Solar Battery -

Scope: This guide applies only to the Dyness PowerBox G2. It covers visual checks and, where your installer demonstrated it at handover, one normal use of the external wake/reset control. Do not remove the cover, disconnect cables, measure voltage, operate unlabelled isolators, change DIP switches or inverter settings, or attempt forced charging. The direct answer A Dyness PowerBox G2 can appear dead because it is asleep, because its external DC breaker is not in the commissioned operating position, or because the battery-management system has stopped output during protection. The front indicator provides the safest first clue: A green flashing "D"...

Read more

GoodWe, Guides, Solar Inverter -

Scope: This guide is for homeowners identifying a current GoodWe ESA 3-10 kW system and its battery modules. The current GoodWe ESA manual covers inverter codes in the GW3K to GW10K EHA-G20 and BHA-G20 families, including GW5K-EHA-G20, plus several G20 and G21 battery variants. It is not a guide for the older GW5048-ESA platform. Identification and document selection are homeowner-safe; opening covers, moving equipment, electrical testing, commissioning and firmware work are for a qualified installer. The direct answer Do not choose a GoodWe manual from the words “ESA”, “5 kW” or “8 kWh” alone. Read the complete model codes from...

Read more

Guides, Solar Inverter, Solis -

If SolisCloud went offline just after you changed broadband provider, replaced the router, renamed the home Wi-Fi network or changed its password, the inverter may be perfectly well while the datalogger is still trying to reach the old network. Reconfigure the datalogger with the new Wi-Fi details, then confirm its status in SolisCloud. Scope and safety This guide covers the Solis S2-WL-ST, S3-WiFi-ST, S4-WiFi-ST and S5-WiFi-ST dataloggers named in Solis's current support guidance. It does not cover the older DLS-W or every Solis communications accessory. Identify the model before starting. These are phone, router and monitoring steps only: do not...

Read more

Dyness, Guides, Solar Battery -

Scope: This guide is for the Dyness DL5.0C Pro low-voltage battery. It is not a guide for the earlier DL5.0C or another Dyness model. It covers visible indicators and evidence a homeowner can safely collect. Do not remove covers, test battery voltage, change DIP switches, disconnect cables, alter inverter settings or update firmware. The direct answer On a Dyness DL5.0C Pro, a flashing red ALM light indicates an alarm, while a steady red light indicates that the battery is in a protection state. The buzzer can accompany some protection events, including over-current or low-voltage conditions. That does not identify the...