{"product_id":"hyundai-dhy8000selr-t-230v-400v-diesel-generator","title":"Hyundai DHY8000SELR-T 230V\/400V Diesel Generator","description":"\u003cp\u003eThe Hyundai DHY8000SELR-T is a switchable-voltage diesel generator for workshops and sites with different electrical requirements. It offers 230V single-phase and 400V three-phase operation; check the selected mode and usable output before connecting any machine.\u003c\/p\u003e\u003cp\u003eThe four-stroke air-cooled 456cc diesel engine is housed in an acoustic enclosure and uses electric key starting. A 30-litre tank is listed with up to 30 hours of runtime, while the stated overall figures are 5.5kW rated and 6kW maximum. These are not per-socket or per-phase allowances.\u003c\/p\u003e\u003cp\u003eA 230V 32A socket and a 400V 16A three-phase socket are listed, along with ATS compatibility. The automatic transfer switch is sold separately and must be selected for the installation. Operate outdoors away from doors, windows and ventilation openings. Never backfeed a building; connection to premises needs a qualified electrician and suitable changeover equipment.\u003c\/p\u003e\u003cdiv id=\"solarboss-inverter-friendly\"\u003e\u003cp\u003eThe DHY8000SELR-T offers ATS compatibility and selectable single-phase or three-phase output. With a matching ATS module, interface cable and external controller that accepts inverter remote-start requests, a compatible Solis hybrid model with generator-control support may start it at low battery state of charge (SOC) and stop it at recovery, subject to operating mode and generator readiness. Start\/stop control does not transfer the house supply. A qualified electrician must verify the selected phase, voltage, frequency and inverter input limits, design AC transfer\/isolation and commission the installation. The single-phase ATS kit is unconfirmed.\u003c\/p\u003e\u003c\/div\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSwitchable 230V single-phase \/ 400V three-phase\u003c\/li\u003e\n\u003cli\u003e5.5kW rated; 6kW maximum overall\u003c\/li\u003e\n\u003cli\u003e456cc air-cooled diesel engine\u003c\/li\u003e\n\u003cli\u003eElectric key start\u003c\/li\u003e\n\u003cli\u003e30L tank and acoustic enclosure\u003c\/li\u003e\n\u003cli\u003eATS-compatible; ATS sold separately\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Friendly\u003c\/strong\u003e – ATS-interface start control is possible with compatible hybrid systems; selectable single\/three-phase operation requires careful electrical matching.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eDHY8000SELR-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated output (overall)\u003c\/th\u003e\n\u003ctd\u003e5.5kW \/ 6.9kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum output (overall)\u003c\/th\u003e\n\u003ctd\u003e6kW \/ 7.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC modes\u003c\/th\u003e\n\u003ctd\u003e230V single-phase \/ 400V three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSockets\u003c\/th\u003e\n\u003ctd\u003e1 × 230V 32A; 1 × 400V 16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC output\u003c\/th\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine\u003c\/th\u003e\n\u003ctd\u003e456cc, air-cooled four-stroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine speed\u003c\/th\u003e\n\u003ctd\u003e3,000rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting\u003c\/th\u003e\n\u003ctd\u003eElectric key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e30L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum stated runtime\u003c\/th\u003e\n\u003ctd\u003eUp to 30 hours; load-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise (stated)\u003c\/th\u003e\n\u003ctd\u003e70dB(A) at 7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATS\u003c\/th\u003e\n\u003ctd\u003eCompatible; sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Start Compatibility\u003c\/th\u003e\n\u003ctd\u003eATS-interface starting needs a separately supplied matching module, cable and controller expressly accepting the compatible inverter’s dry-contact start\/stop requests. Mains-failure sensing alone does not provide SOC control. Compatibility with the 100A single-phase ATS kit is unconfirmed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy8000selr-t-0-manual.pdf?v=1792675799\" target=\"_blank\" rel=\"noopener\"\u003eDHY8000SELR-T User manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eManufacturer videos\u003c\/h2\u003e\u003ch3\u003eHow to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/k2sH21kc8Ws\" title=\"How to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eDiagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/COjOWKpFjC4\" title=\"Diagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eBe Prepared for Power Cuts This Winter With Hyundai 3000rpm Diesel Generators Single and Three Phase\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/7-ik433veA4\" title=\"Be Prepared for Power Cuts This Winter With Hyundai 3000rpm Diesel Generators Single and Three Phase\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":55696809165129,"sku":"DHY8000SELR-T","price":1617.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/hyundai-dhy8000selr-t-230v-400v-diesel-generator-1.jpg?v=1792674996","url":"https:\/\/solarboss.ie\/de\/products\/hyundai-dhy8000selr-t-230v-400v-diesel-generator","provider":"Solarboss","version":"1.0","type":"link"}