{"title":"Inverter Friendly Generators","description":"\u003cp\u003eWant a diesel generator that can work with a hybrid solar and battery system? Our Inverter Friendly Generators collection highlights models with documented remote-start interfaces, allowing automatic start\/stop integration where the inverter and generator controls are properly matched. This can be useful in Ireland when solar production is low and stored battery energy needs support.\u003c\/p\u003e\u003cp\u003eThree models use ATS-interface starting: the Hyundai DHY6000SE, DHY8000SELR and selectable single\/three-phase DHY8000SELR-T. These need a suitable generator-side ATS module, matching interface cable and a separately supplied controller that explicitly accepts a hybrid inverter remote-start request. Mains-failure sensing alone does not provide battery SOC control. The DHY12500SE and DHY18COM-1 instead offer two-wire remote-start interfaces that may work with compatible inverter programmable dry contacts, subject to correct control ratings and configuration.\u003c\/p\u003e\u003cp\u003eA compatible Solis hybrid model with generator-control support may offer start and stop thresholds based on battery state of charge, but its generator-control feature does not establish electrical input compatibility. Starting a generator also does not transfer your house supply. A qualified electrician must confirm phase, voltage, frequency, inverter input limits and isolation\/transfer arrangements before commissioning. Here, 'Inverter Friendly' describes control integration, not inverter-generator construction or certified pure-sine-wave output. Browse \u003ca href=\"\/collections\/diesel-generators\"\u003eDiesel Generators\u003c\/a\u003e and \u003ca href=\"\/collections\/generator-accessories\"\u003eGenerator Accessories\u003c\/a\u003e for related options.\u003c\/p\u003e","products":[{"product_id":"hyundai-dhy8000selr-6kw-single-phase-diesel-generator","title":"Hyundai DHY8000SELR 6kW Single-Phase Diesel Generator","description":"\u003cp\u003eThe Hyundai DHY8000SELR is a long-run diesel standby generator for temporary power where the mains supply is unavailable. Its figures distinguish 5.5kW rated output from a higher 6kW maximum, making it important to plan normal loads around the rated value.\u003c\/p\u003e\u003cp\u003eA 452cc air-cooled diesel engine, electric key start and AVR alternator form the core of the machine. The 30-litre fuel tank is stated to support up to 30 hours under favourable load conditions. A sound-reducing enclosure helps manage noise, with 70dB(A) quoted at 7m.\u003c\/p\u003e\u003cp\u003eThe generator supports a separately specified automatic transfer switch (ATS), but no ATS is included as part of the documented configuration. Suitable electrical design is essential for standby connection. Operate outdoors away from doors, windows and ventilation openings. Never backfeed a building; connection to premises needs a qualified electrician and suitable changeover equipment.\u003c\/p\u003e\u003csection id=\"solarboss-ats-accessory\" style=\"border:1px solid #d9dfe8;border-radius:12px;padding:18px;margin:20px 0\"\u003e\u003ch3\u003eSuggested generator accessory\u003c\/h3\u003e\n\u003ca href=\"\/products\/100a-compact-automatic-transfer-switch-kit-1365079\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/100a-compact-automatic-transfer-switch-kit-1365079-1.png?v=1792685943\" alt=\"100A Compact Automatic Transfer Switch Kit\" width=\"180\" loading=\"lazy\" style=\"width:180px;max-width:100%;height:auto\"\u003e\u003c\/a\u003e\u003cp\u003e\u003cstrong\u003eOptional Automatic Transfer Switch:\u003c\/strong\u003e For compatible single-phase standby installations, the \u003ca href=\"\/products\/100a-compact-automatic-transfer-switch-kit-1365079\"\u003e100A Compact Automatic Transfer Switch Kit\u003c\/a\u003e is available as a separately sold accessory. It enables automatic mains\/generator changeover when correctly integrated with supported generator controls. A qualified electrician must confirm compatibility and carry out the installation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/products\/100a-compact-automatic-transfer-switch-kit-1365079\" style=\"display:inline-block;padding:10px 18px;background:#ffad32;color:#102c55;border-radius:6px;font-weight:700\"\u003eView ATS kit and availability\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\u003cdiv id=\"solarboss-inverter-friendly\"\u003e\u003cp\u003eThe DHY8000SELR can form part of a battery-triggered generator setup when its ATS standard module is fitted internally and a suitable external controller and cable are connected through the ATS interface. A compatible Solis hybrid model with generator-control support may request a start at low battery state of charge (SOC) and a stop at the configured recovery threshold, subject to operating mode and generator readiness. Start\/stop control does not transfer the house supply. A qualified electrician must verify phase, voltage, frequency and inverter input limits, design AC transfer\/isolation and commission the system.\u003c\/p\u003e\u003c\/div\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5.5kW rated; 6kW maximum\u003c\/li\u003e\n\u003cli\u003e230V single-phase diesel set\u003c\/li\u003e\n\u003cli\u003e30L long-run tank\u003c\/li\u003e\n\u003cli\u003eElectric start; AVR alternator\u003c\/li\u003e\n\u003cli\u003eSilenced housing\u003c\/li\u003e\n\u003cli\u003eATS-compatible; ATS sold separately\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Friendly\u003c\/strong\u003e – ATS-interface automatic starting is possible with compatible hybrid systems and separately supplied equipment accepting inverter remote-start requests.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eDHY8000SELR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated output\u003c\/th\u003e\n\u003ctd\u003e5.5kW \/ 6.8kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum output\u003c\/th\u003e\n\u003ctd\u003e6kW \/ 7.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC voltage\u003c\/th\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine\u003c\/th\u003e\n\u003ctd\u003e452cc air-cooled diesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine speed\u003c\/th\u003e\n\u003ctd\u003e3,000rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting\u003c\/th\u003e\n\u003ctd\u003eElectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e30L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum stated runtime\u003c\/th\u003e\n\u003ctd\u003eUp to 30 hours; load-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise (stated)\u003c\/th\u003e\n\u003ctd\u003e70dB(A) at 7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e158kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATS\u003c\/th\u003e\n\u003ctd\u003eCompatible; separate equipment required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Start Compatibility\u003c\/th\u003e\n\u003ctd\u003eATS-interface starting via an internally fitted ATS standard module and matching external cable\/controller. The controller must accept the compatible inverter’s dry-contact start\/stop requests; mains-failure sensing alone does not provide SOC control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy6000se-0-manual.pdf?v=1792675732\" target=\"_blank\" rel=\"noopener\"\u003eDHY8000SELR User manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy8000selr-1-specifications.pdf?v=1792675732\" target=\"_blank\" rel=\"noopener\"\u003eDHY8000SELR Specification sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eManufacturer videos\u003c\/h2\u003e\u003ch3\u003eHow to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/k2sH21kc8Ws\" title=\"How to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eDiagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/COjOWKpFjC4\" title=\"Diagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":55696807199049,"sku":"DHY8000SELR","price":1617.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/hyundai-dhy8000selr-6kw-single-phase-diesel-generator-1.jpg?v=1792674992"},{"product_id":"hyundai-dhy18com-1-1500rpm-single-phase-diesel-generator","title":"Hyundai DHY18COM-1 1500rpm Single-Phase Diesel Generator","description":"\u003cp\u003eThe Hyundai DHY18COM-1 is a larger stationary-style diesel generator intended for planned business and property standby applications or appropriately specified prime-power installations. It uses a 1,500rpm diesel engine, making duty cycle and installation design key considerations when comparing it with faster-running portable models.\u003c\/p\u003e\u003cp\u003eThe supplied facts identify a four-cylinder, 1,809cc, water-cooled engine and a 230V single-phase, 50Hz AC supply. A DSE6120 MKIII control panel supports monitoring and generator controls, while a brushless AVR-regulated alternator and busbar output are listed. A 40-litre fuel tank is provided.\u003c\/p\u003e\u003cp\u003eThe source contains conflicting prime-versus-standby power labels, so no unverified watt or kVA duty rating is repeated here; confirm the applicable rating before specifying a load. ATS\/MTS compatibility is listed, but transfer equipment is not documented as included. Operate outdoors away from doors, windows and ventilation openings. Never backfeed a building; connection to premises needs a qualified electrician and suitable changeover equipment.\u003c\/p\u003e\u003cdiv id=\"solarboss-inverter-friendly\"\u003e\u003cp\u003eThe DHY18COM-1 has a two-wire volt-free remote-start interface. A compatible Solis hybrid model with generator-control support may request a start when battery state of charge (SOC) falls below its configured threshold and a stop after recovery, subject to inverter operating mode and generator readiness. Start\/stop control does not transfer the house supply; a full load-transfer ATS is not required just to send the control request. A qualified electrician must check contact ratings, isolation, phase, voltage, frequency and inverter input limits, then design AC transfer\/isolation and commission the installation.\u003c\/p\u003e\u003c\/div\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1,500rpm water-cooled diesel generator\u003c\/li\u003e\n\u003cli\u003e230V single-phase output\u003c\/li\u003e\n\u003cli\u003eDSE6120 MKIII control panel\u003c\/li\u003e\n\u003cli\u003eBrushless AVR alternator\u003c\/li\u003e\n\u003cli\u003eATS\/MTS compatible; switching equipment separate\u003c\/li\u003e\n\u003cli\u003eBusbar connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Friendly\u003c\/strong\u003e – Two-wire volt-free remote starting can integrate with compatible hybrid inverter programmable dry contacts after professional checks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eDHY18COM-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC voltage\u003c\/th\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated engine speed\u003c\/th\u003e\n\u003ctd\u003e1,500rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine\u003c\/th\u003e\n\u003ctd\u003eFour-cylinder, 1,809cc, water-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl panel\u003c\/th\u003e\n\u003ctd\u003eDSE6120 MKIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlternator\u003c\/th\u003e\n\u003ctd\u003eBrushless, AVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eBusbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e40L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e520kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e1,600 × 740 × 825mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATS\/MTS\u003c\/th\u003e\n\u003ctd\u003eCompatible; separate equipment required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Start Compatibility\u003c\/th\u003e\n\u003ctd\u003eTwo-wire volt-free relay start interface. Compatible inverter programmable dry-contact start\/stop possible with verified contact ratings, suitable cable and isolation where required. A load-transfer ATS is not inherently required merely to request start\/stop.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy18com-1-0-manual.pdf?v=1792675797\" target=\"_blank\" rel=\"noopener\"\u003eDHY18COM-1 User manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":55696808051017,"sku":"DHY18COM-1","price":4796.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/hyundai-dhy18com-1-1500rpm-single-phase-diesel-generator-1.png?v=1792674994"},{"product_id":"hyundai-dhy8000selr-t-230v-400v-diesel-generator","title":"Hyundai DHY8000SELR-T 230V\/400V Diesel Generator","description":"\u003cp\u003eThe Hyundai DHY8000SELR-T is a switchable-voltage diesel generator for workshops and sites with different electrical requirements. It offers 230V single-phase and 400V three-phase operation; check the selected mode and usable output before connecting any machine.\u003c\/p\u003e\u003cp\u003eThe four-stroke air-cooled 456cc diesel engine is housed in an acoustic enclosure and uses electric key starting. A 30-litre tank is listed with up to 30 hours of runtime, while the stated overall figures are 5.5kW rated and 6kW maximum. These are not per-socket or per-phase allowances.\u003c\/p\u003e\u003cp\u003eA 230V 32A socket and a 400V 16A three-phase socket are listed, along with ATS compatibility. The automatic transfer switch is sold separately and must be selected for the installation. Operate outdoors away from doors, windows and ventilation openings. Never backfeed a building; connection to premises needs a qualified electrician and suitable changeover equipment.\u003c\/p\u003e\u003cdiv id=\"solarboss-inverter-friendly\"\u003e\u003cp\u003eThe DHY8000SELR-T offers ATS compatibility and selectable single-phase or three-phase output. With a matching ATS module, interface cable and external controller that accepts inverter remote-start requests, a compatible Solis hybrid model with generator-control support may start it at low battery state of charge (SOC) and stop it at recovery, subject to operating mode and generator readiness. Start\/stop control does not transfer the house supply. A qualified electrician must verify the selected phase, voltage, frequency and inverter input limits, design AC transfer\/isolation and commission the installation. The single-phase ATS kit is unconfirmed.\u003c\/p\u003e\u003c\/div\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSwitchable 230V single-phase \/ 400V three-phase\u003c\/li\u003e\n\u003cli\u003e5.5kW rated; 6kW maximum overall\u003c\/li\u003e\n\u003cli\u003e456cc air-cooled diesel engine\u003c\/li\u003e\n\u003cli\u003eElectric key start\u003c\/li\u003e\n\u003cli\u003e30L tank and acoustic enclosure\u003c\/li\u003e\n\u003cli\u003eATS-compatible; ATS sold separately\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Friendly\u003c\/strong\u003e – ATS-interface start control is possible with compatible hybrid systems; selectable single\/three-phase operation requires careful electrical matching.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eDHY8000SELR-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated output (overall)\u003c\/th\u003e\n\u003ctd\u003e5.5kW \/ 6.9kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum output (overall)\u003c\/th\u003e\n\u003ctd\u003e6kW \/ 7.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC modes\u003c\/th\u003e\n\u003ctd\u003e230V single-phase \/ 400V three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSockets\u003c\/th\u003e\n\u003ctd\u003e1 × 230V 32A; 1 × 400V 16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDC output\u003c\/th\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine\u003c\/th\u003e\n\u003ctd\u003e456cc, air-cooled four-stroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine speed\u003c\/th\u003e\n\u003ctd\u003e3,000rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting\u003c\/th\u003e\n\u003ctd\u003eElectric key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e30L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum stated runtime\u003c\/th\u003e\n\u003ctd\u003eUp to 30 hours; load-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNoise (stated)\u003c\/th\u003e\n\u003ctd\u003e70dB(A) at 7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATS\u003c\/th\u003e\n\u003ctd\u003eCompatible; sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Start Compatibility\u003c\/th\u003e\n\u003ctd\u003eATS-interface starting needs a separately supplied matching module, cable and controller expressly accepting the compatible inverter’s dry-contact start\/stop requests. Mains-failure sensing alone does not provide SOC control. Compatibility with the 100A single-phase ATS kit is unconfirmed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy8000selr-t-0-manual.pdf?v=1792675799\" target=\"_blank\" rel=\"noopener\"\u003eDHY8000SELR-T User manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eManufacturer videos\u003c\/h2\u003e\u003ch3\u003eHow to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/k2sH21kc8Ws\" title=\"How to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eDiagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/COjOWKpFjC4\" title=\"Diagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eBe Prepared for Power Cuts This Winter With Hyundai 3000rpm Diesel Generators Single and Three Phase\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/7-ik433veA4\" title=\"Be Prepared for Power Cuts This Winter With Hyundai 3000rpm Diesel Generators Single and Three Phase\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":55696809165129,"sku":"DHY8000SELR-T","price":1617.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/hyundai-dhy8000selr-t-230v-400v-diesel-generator-1.jpg?v=1792674996"},{"product_id":"hyundai-dhy12500se-10kw-standby-diesel-generator","title":"Hyundai DHY12500SE 10kW Standby Diesel Generator","description":"\u003cp\u003eThe Hyundai DHY12500SE is a 230V standby diesel generator aimed at larger property and small business loads that require a properly installed alternative supply. Its stated maximum output is 10kW (12.5kVA); a separate continuous watt rating is not clearly established in the supplied brief.\u003c\/p\u003e\u003cp\u003eThe twin-cylinder air-cooled engine uses electric key starting, with a 60-litre fuel tank stated to run for up to 18 hours at quarter load. A silenced enclosure, AVR regulation and control-panel information for volts, frequency and running hours are documented.\u003c\/p\u003e\u003cp\u003eThe unit includes 230V 32A and 63A connections and is compatible with two-wire starting and optional ATS equipment. An ATS is not included, and connection to a property requires correctly designed transfer protection. Operate outdoors away from doors, windows and ventilation openings. Never backfeed a building; connection to premises needs a qualified electrician and suitable changeover equipment.\u003c\/p\u003e\u003cdiv id=\"solarboss-inverter-friendly\"\u003e\u003cp\u003eThe DHY12500SE supports two-wire remote starting from a compatible hybrid inverter's programmed dry contact. A compatible Solis hybrid model with generator-control support may request starting below a set battery state of charge (SOC) and stopping at its recovery threshold, subject to operating mode and generator readiness. Start\/stop control does not transfer the house supply, and a load-transfer ATS is not inherently needed for the signal alone. A qualified electrician must check contact ratings, isolation where necessary, phase, voltage, frequency and inverter input limits, then design AC transfer\/isolation and commission the system.\u003c\/p\u003e\u003c\/div\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10kW \/ 12.5kVA stated maximum\u003c\/li\u003e\n\u003cli\u003e230V diesel standby generator\u003c\/li\u003e\n\u003cli\u003eTwin-cylinder air-cooled engine\u003c\/li\u003e\n\u003cli\u003e60L tank; up to 18 hours at quarter load\u003c\/li\u003e\n\u003cli\u003eElectric key start and AVR\u003c\/li\u003e\n\u003cli\u003eATS compatible; not included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Friendly\u003c\/strong\u003e – Documented two-wire remote start enables professionally configured automatic start\/stop requests from compatible hybrid inverter dry contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eDHY12500SE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum output\u003c\/th\u003e\n\u003ctd\u003e10kW \/ 12.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC voltage\u003c\/th\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine\u003c\/th\u003e\n\u003ctd\u003eTwin-cylinder, air-cooled diesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine speed\u003c\/th\u003e\n\u003ctd\u003e3,000rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting\u003c\/th\u003e\n\u003ctd\u003eElectric key\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e60L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRuntime at 25% load\u003c\/th\u003e\n\u003ctd\u003eUp to 18 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC connections\u003c\/th\u003e\n\u003ctd\u003e230V 32A and 63A stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage regulation\u003c\/th\u003e\n\u003ctd\u003eAVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e295kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (L × W × H)\u003c\/th\u003e\n\u003ctd\u003e1,175 × 695 × 1,050mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATS\u003c\/th\u003e\n\u003ctd\u003eCompatible; not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Start Compatibility\u003c\/th\u003e\n\u003ctd\u003eKey, ATS and two-wire remote-start options. Compatible inverter programmable dry contact may request start\/stop with suitable control cable, checked contact ratings and isolation where needed. A load-transfer ATS is not needed solely to issue start\/stop commands.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy12500se-0-manual.pdf?v=1792675730\" target=\"_blank\" rel=\"noopener\"\u003eDHY12500SE User manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy12500se-1-specifications.pdf?v=1792675731\" target=\"_blank\" rel=\"noopener\"\u003eDHY12500SE Specification sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eManufacturer videos\u003c\/h2\u003e\u003ch3\u003eBe Prepared for Power Cuts This Winter With Hyundai 3000rpm Diesel Generators Single and Three Phase\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/7-ik433veA4\" title=\"Be Prepared for Power Cuts This Winter With Hyundai 3000rpm Diesel Generators Single and Three Phase\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":55696809328969,"sku":"DHY12500SE","price":3766.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/hyundai-dhy12500se-10kw-standby-diesel-generator-1.jpg?v=1792674998"},{"product_id":"hyundai-dhy6000se-5-2kw-standby-diesel-generator","title":"Hyundai DHY6000SE 5.2kW Standby Diesel Generator","description":"\u003cp\u003eThe Hyundai DHY6000SE is a compact enclosed diesel generator for outdoor standby and temporary power applications. Its specified 5.2kW maximum output should be distinguished from a continuous rating, which is not separately confirmed in the supplied information.\u003c\/p\u003e\u003cp\u003eThe D420 four-stroke diesel engine has electric starting, AVR voltage regulation and an automatic low-oil shutdown. A 16-litre fuel tank supports a stated runtime of up to 16 hours at 50% load, with a sound-attenuating canopy to reduce operating noise.\u003c\/p\u003e\u003cp\u003eThe connection panel includes 115V 16A and 32A sockets and a 230V 32A socket. Optional ATS compatibility is documented, but the transfer switch is not included. Operate outdoors away from doors, windows and ventilation openings. Never backfeed a building; connection to premises needs a qualified electrician and suitable changeover equipment.\u003c\/p\u003e\u003csection id=\"solarboss-ats-accessory\" style=\"border:1px solid #d9dfe8;border-radius:12px;padding:18px;margin:20px 0\"\u003e\u003ch3\u003eSuggested generator accessory\u003c\/h3\u003e\n\u003ca href=\"\/products\/100a-compact-automatic-transfer-switch-kit-1365079\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/100a-compact-automatic-transfer-switch-kit-1365079-1.png?v=1792685943\" alt=\"100A Compact Automatic Transfer Switch Kit\" width=\"180\" loading=\"lazy\" style=\"width:180px;max-width:100%;height:auto\"\u003e\u003c\/a\u003e\u003cp\u003e\u003cstrong\u003eOptional Automatic Transfer Switch:\u003c\/strong\u003e For compatible single-phase standby installations, the \u003ca href=\"\/products\/100a-compact-automatic-transfer-switch-kit-1365079\"\u003e100A Compact Automatic Transfer Switch Kit\u003c\/a\u003e is available as a separately sold accessory. It enables automatic mains\/generator changeover when correctly integrated with supported generator controls. A qualified electrician must confirm compatibility and carry out the installation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/products\/100a-compact-automatic-transfer-switch-kit-1365079\" style=\"display:inline-block;padding:10px 18px;background:#ffad32;color:#102c55;border-radius:6px;font-weight:700\"\u003eView ATS kit and availability\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\u003cdiv id=\"solarboss-inverter-friendly\"\u003e\u003cp\u003eWith the correct ATS standard module fitted inside the generator, the DHY6000SE can receive start\/stop requests through a matching external cable and controller. A compatible Solis hybrid model with generator-control support may request starting below a configured battery state of charge (SOC) threshold and stopping at recovery, depending on operating mode and generator readiness. Start\/stop control does not transfer the house supply. A qualified electrician must check phase, voltage, frequency and inverter input limits, design separate AC connection and transfer\/isolation, and commission the complete installation.\u003c\/p\u003e\u003c\/div\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5.2kW stated maximum output\u003c\/li\u003e\n\u003cli\u003eDiesel generator in acoustic enclosure\u003c\/li\u003e\n\u003cli\u003e115V and 230V sockets\u003c\/li\u003e\n\u003cli\u003eElectric starting and AVR\u003c\/li\u003e\n\u003cli\u003e16L fuel tank\u003c\/li\u003e\n\u003cli\u003eATS compatibility; transfer switch separate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Friendly\u003c\/strong\u003e – Automatic-start integration with compatible hybrid systems requires a separately supplied ATS module and controller accepting inverter start requests.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eDHY6000SE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum output\u003c\/th\u003e\n\u003ctd\u003e5.2kW \/ 6.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC voltage\u003c\/th\u003e\n\u003ctd\u003e115V \/ 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAC sockets\u003c\/th\u003e\n\u003ctd\u003e1 × 115V 16A; 1 × 115V 32A; 1 × 230V 32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEngine\u003c\/th\u003e\n\u003ctd\u003eHyundai D420 four-stroke diesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting\u003c\/th\u003e\n\u003ctd\u003eElectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e16L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRuntime at 50% load\u003c\/th\u003e\n\u003ctd\u003eUp to 16 hours (stated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage regulation\u003c\/th\u003e\n\u003ctd\u003eAVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLow-oil shutdown\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eATS\u003c\/th\u003e\n\u003ctd\u003eCompatible; not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Start Compatibility\u003c\/th\u003e\n\u003ctd\u003eATS-interface starting. ATS standard module fitted internally; matching external cable and controller must accept the compatible inverter’s dry-contact start\/stop requests. Mains-failure sensing alone does not provide SOC control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/dhy6000se-0-manual.pdf?v=1792675732\" target=\"_blank\" rel=\"noopener\"\u003eDHY6000SE User manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eManufacturer videos\u003c\/h2\u003e\u003ch3\u003eHow to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/k2sH21kc8Ws\" title=\"How to Change the Brushes on a DHY6\/8000SE\/LR Hyundai Diesel Generator\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eDiagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\u003c\/h3\u003e\u003cdiv style=\"aspect-ratio:16\/9;max-width:800px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/COjOWKpFjC4\" title=\"Diagnosing No Output on your Hyundai 3000rpm Generator (DHY6000SE, DHY8000SELR, DHY8000SELR-T)\" width=\"800\" height=\"450\" loading=\"lazy\" style=\"width:100%;height:100%;border:0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":55696810082633,"sku":"DHY6000SE","price":1292.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/2248\/0534\/files\/hyundai-dhy6000se-5-2kw-standby-diesel-generator-1.jpg?v=1792675002"}],"url":"https:\/\/solarboss.ie\/collections\/inverter-friendly-generators.oembed","provider":"Solarboss","version":"1.0","type":"link"}